MetalHighly absorbent
Data source
PTB reference data
Physikalisch-Technische Bundesanstalt
Source: C.M.Harris, Noise Control in Buildings, McGraw Hill 1994
Value from the PTB table, not verified
Steel deck, pan perforated absorptive backing
Acustadek BF
PTB reference data
Original description
Steel deck, pan perforated absorptive backing
Material properties
Manufacturer: ASC Pacific
Thickness: 1 1/2 inch
Wall distance: 0 in
Backing: absorptive backing
Measurement data
Sound absorption
Reverberation chamber (ASTM C423 / ISO 354)
NRC
0.80
derived from ISO 354 lab data
Frequency values
αp nach ISO 11654
| f (Hz) | 125 | 250 | 500 | 1k | 2k | 4k |
|---|---|---|---|---|---|---|
| αp | 0.55 | 0.60 | 0.75 | 0.95 | 0.85 | 0.55 |
Create a permanent free account — Access frequency bands, variants and export.
Free. No password required.
Value from the PTB table, not verified
NRC: 0.80 (derived from ISO 354 lab data)
Measured values as a table (1 measurement)
| Build-up | NRC | 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz |
|---|---|---|---|---|---|---|---|
| 1 1/2 inch · 4.3 lb/ft² · 0 | 0.80 | 0.53 | 0.58 | 0.75 | 0.97 | 0.86 | 0.57 |
Measured values as a table (1 measurement)
Access frequency bands, variants and export. Create a permanent free account
Last updated: