Plafotherm DS heating and cooling ceiling raft
Sabins/unit 6.5–52 at 1 kHz
Manufacturer
Lindner Group
Lindner Group, Arnstorf: metal ceilings, heating and cooling ceilings, raised floors, wall and ceiling linings and the MUTE+ sound absorber line.
Description
Freely suspended heating and cooling ceiling raft of perforated metal with acoustic fleece and an optional acoustic insert. Nominal cooling capacity 135 to 139 W/m² at 10 K per EN 14240, nominal heating capacity 163 to 167 W/m² at 15 K per EN 14037:2003, depending on the register and referred to the active area. Recycled content 45.8 per cent (DS 320).
Technical data
Measurement data
Sound absorption
Reverberation chamber (ASTM C423 / ISO 354)· 24 variants
Frequency values
Create a permanent free account. Access frequency bands, variants and export.
Free. No password required.
| Compare | Value | ||||
|---|---|---|---|---|---|
| Rg 1.8 - 19 | 9.8 in | ceiling raft 195 x 35 in, with heat-conducting profile | 0.79 in | Sabins/unit52 | |
| BASICline Rg 2.5-16 | 9.8 in | ceiling raft 35 x 157 in | 1.6 in all around | Sabins/unit39 | |
| BASICline Rg 2.5-16, smooth edge | 9.8 in | ceiling raft 35 x 157 in | 1.6 in on the long side | Sabins/unit36 | |
| Rg 2.5 - 16 | 16 in | ceiling raft 138 x 35 in, acoustic heat-conducting profile | — | Sabins/unit29 | |
| Rv 2.0 - 20 | 7.9 in | ceiling raft 68 x 55 in, with heat-conducting profile | 0.79 in | Sabins/unit25 | |
| Rg 0.8 - 5 | 7.9 in | ceiling raft 94 x 47 in, with heat-conducting profile | 0.79 in (20 % coverage) | Sabins/unit22 | |
| BASICline Rg 2.5-16 | 9.8 in | ceiling raft 35 x 79 in, 2 units | 1.6 in all around | Sabins/unit20 | |
| Rg 0.8 - 5 Crystal | 7.9 in | ceiling raft 81 x 41 in, with heat-conducting profile | 1.2 in | Sabins/unit18 | |
| Rg 0.8 - 5 Pixel | 7.9 in | ceiling raft 79 x 39 in, with heat-conducting profile | 1.2 in | Sabins/unit18 | |
| Rg 0.8 - 5 Paper | 7.9 in | ceiling raft 79 x 39 in, with heat-conducting profile | 1.2 in | Sabins/unit17 | |
| Rg 0.8 - 5 | 7.9 in | ceiling raft 94 x 47 in, with heat-conducting profile | — | Sabins/unit16 | |
| Rg 0.8 - 5 Crystal | 7.9 in | ceiling raft 81 x 41 in, with heat-conducting profile | 1.2 in (50 % coverage) | Sabins/unit15 | |
| Rg 3.0 - 20 | 7.9 in | ceiling raft 43 x 39 in, acoustic heat-conducting profile | 0.79 in | Sabins/unit14 | |
| Rg 0.8 - 5 Paper | 7.9 in | ceiling raft 79 x 39 in, with heat-conducting profile | 1.2 in (50 % coverage) | Sabins/unit14 | |
| Rg 0.8 - 5 Pixel | 7.9 in | ceiling raft 79 x 39 in, with heat-conducting profile | 1.2 in (50 % coverage) | Sabins/unit14 | |
| REGULARline Rg 0.8-5 | 7.9 in | ceiling raft 42 x 42 in, 3 units | 1.6 in all around | Sabins/unit13 | |
| Rv 2.0 - 20 | 7.9 in | ceiling raft 68 x 55 in, with heat-conducting profile | — | Sabins/unit12 | |
| Rg 3.0 - 20 | 7.9 in | ceiling raft 43 x 39 in, acoustic heat-conducting profile | 0.79 in (30 % coverage) | Sabins/unit12 | |
| Rg 3.0 - 20 | 7.9 in | ceiling raft 43 x 39 in, acoustic heat-conducting profile | — | Sabins/unit9.7 | |
| REGULARline Rg 0.8-5 | 7.9 in | ceiling raft 42 x 42 in, 3 units | 1.6 in on the long side | Sabins/unit9.7 | |
| Rg 0.8 - 5 Paper | 7.9 in | ceiling raft 79 x 39 in, with heat-conducting profile | — | Sabins/unit6.5 | |
| Rg 0.8 - 5 Crystal | 7.9 in | ceiling raft 81 x 41 in, with heat-conducting profile | — | Sabins/unit6.5 | |
| Rg 0.8 - 5 Pixel | 7.9 in | ceiling raft 79 x 39 in, with heat-conducting profile | — | Sabins/unit6.5 | |
| BASICline Rg 2.5-16 | 9.8 in | ceiling raft 35 x 157 in | — | — |
Test report: H100330_2
Measurement date: 03/30/2010
Test setup: ceiling raft 195 x 35 in, with heat-conducting profile
Absorber: 0.79 in
Measured values as a table (24 measurements)
| Build-up | NRC | 100 Hz | 125 Hz | 160 Hz | 200 Hz | 250 Hz | 315 Hz | 400 Hz | 500 Hz | 630 Hz | 800 Hz | 1000 Hz | 1250 Hz | 1600 Hz | 2000 Hz | 2500 Hz | 3150 Hz | 4000 Hz | 5000 Hz |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rv 2.0 - 20 · 7.9 in · ceiling raft 68 x 55 in, with heat-conducting profile (sabins/unit) | – | 3.2 | 3.2 | 7.5 | 11 | 15 | 18 | 19 | 19 | 18 | 14 | 12 | 14 | 13 | 12 | 13 | 12 | 12 | 11 |
| Rv 2.0 - 20 · 7.9 in · ceiling raft 68 x 55 in, with heat-conducting profile (sabins/unit) | – | 5.4 | 7.5 | 14 | 19 | 24 | 27 | 28 | 28 | 27 | 25 | 25 | 25 | 24 | 20 | 19 | 17 | 16 | 16 |
| Rg 1.8 - 19 · 9.8 in · ceiling raft 195 x 35 in, with heat-conducting profile (sabins/unit) | – | 20 | 33 | 33 | 38 | 46 | 58 | 56 | 52 | 44 | 45 | 52 | 48 | 46 | 43 | 40 | 38 | 33 | 32 |
| Rg 0.8 - 5 · 7.9 in · ceiling raft 94 x 47 in, with heat-conducting profile (sabins/unit) | – | 5.4 | 7.5 | 12 | 17 | 23 | 25 | 25 | 24 | 23 | 22 | 22 | 20 | 19 | 19 | 18 | 19 | 20 | 23 |
| Rg 0.8 - 5 · 7.9 in · ceiling raft 94 x 47 in, with heat-conducting profile (sabins/unit) | – | 4.3 | 9.7 | 15 | 15 | 20 | 23 | 22 | 22 | 19 | 18 | 16 | 16 | 15 | 13 | 13 | 13 | 14 | 17 |
| Rg 3.0 - 20 · 7.9 in · ceiling raft 43 x 39 in, acoustic heat-conducting profile (sabins/unit) | – | 1.1 | 5.4 | 8.6 | 8.6 | 12 | 15 | 16 | 16 | 16 | 14 | 14 | 15 | 14 | 14 | 13 | 12 | 12 | 12 |
| Rg 3.0 - 20 · 7.9 in · ceiling raft 43 x 39 in, acoustic heat-conducting profile (sabins/unit) | – | 1.1 | 4.3 | 6.5 | 6.5 | 9.7 | 13 | 13 | 13 | 14 | 12 | 12 | 13 | 12 | 12 | 11 | 11 | 11 | 9.7 |
| Rg 3.0 - 20 · 7.9 in · ceiling raft 43 x 39 in, acoustic heat-conducting profile (sabins/unit) | – | 1.1 | 3.2 | 6.5 | 6.5 | 8.6 | 12 | 12 | 12 | 13 | 11 | 9.7 | 11 | 11 | 9.7 | 8.6 | 9.7 | 8.6 | 7.5 |
| Rg 2.5 - 16 · 16 in · ceiling raft 138 x 35 in, acoustic heat-conducting profile (sabins/unit) | – | 6.5 | 20 | 30 | 27 | 31 | 30 | 28 | 26 | 30 | 28 | 29 | 30 | 29 | 27 | 25 | 24 | 20 | 19 |
| Rg 0.8 - 5 Paper · 7.9 in · ceiling raft 79 x 39 in, with heat-conducting profile (sabins/unit) | – | 3.2 | 6.5 | 14 | 18 | 17 | 19 | 19 | 18 | 17 | 16 | 17 | 17 | 16 | 16 | 15 | 14 | 14 | 14 |
| Rg 0.8 - 5 Paper · 7.9 in · ceiling raft 79 x 39 in, with heat-conducting profile (sabins/unit) | – | 1.1 | 2.2 | 8.6 | 9.7 | 9.7 | 9.7 | 9.7 | 8.6 | 7.5 | 6.5 | 6.5 | 7.5 | 7.5 | 7.5 | 7.5 | 6.5 | 6.5 | 7.5 |
| Rg 0.8 - 5 Paper · 7.9 in · ceiling raft 79 x 39 in, with heat-conducting profile (sabins/unit) | – | 2.2 | 5.4 | 12 | 13 | 13 | 15 | 17 | 15 | 15 | 13 | 14 | 14 | 14 | 15 | 14 | 14 | 13 | 15 |
| Rg 0.8 - 5 Crystal · 7.9 in · ceiling raft 81 x 41 in, with heat-conducting profile (sabins/unit) | – | 3.2 | 7.5 | 14 | 17 | 17 | 19 | 19 | 19 | 18 | 17 | 18 | 19 | 18 | 18 | 18 | 17 | 16 | 17 |
| Rg 0.8 - 5 Crystal · 7.9 in · ceiling raft 81 x 41 in, with heat-conducting profile (sabins/unit) | – | 1.1 | 3.2 | 9.7 | 9.7 | 8.6 | 9.7 | 8.6 | 7.5 | 7.5 | 6.5 | 6.5 | 7.5 | 7.5 | 8.6 | 8.6 | 8.6 | 8.6 | 11 |
| Rg 0.8 - 5 Crystal · 7.9 in · ceiling raft 81 x 41 in, with heat-conducting profile (sabins/unit) | – | 2.2 | 5.4 | 12 | 13 | 13 | 15 | 16 | 16 | 15 | 14 | 15 | 16 | 16 | 17 | 16 | 16 | 15 | 17 |
| Rg 0.8 - 5 Pixel · 7.9 in · ceiling raft 79 x 39 in, with heat-conducting profile (sabins/unit) | – | 2.2 | 6.5 | 13 | 16 | 16 | 17 | 19 | 18 | 18 | 16 | 18 | 17 | 17 | 17 | 17 | 16 | 15 | 16 |
| Rg 0.8 - 5 Pixel · 7.9 in · ceiling raft 79 x 39 in, with heat-conducting profile (sabins/unit) | – | 1.1 | 2.2 | 7.5 | 8.6 | 7.5 | 9.7 | 9.7 | 8.6 | 7.5 | 5.4 | 6.5 | 7.5 | 7.5 | 7.5 | 7.5 | 7.5 | 7.5 | 9.7 |
| Rg 0.8 - 5 Pixel · 7.9 in · ceiling raft 79 x 39 in, with heat-conducting profile (sabins/unit) | – | 2.2 | 5.4 | 12 | 12 | 13 | 15 | 17 | 15 | 14 | 14 | 14 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
| REGULARline Rg 0.8-5 · 7.9 in · ceiling raft 42 x 42 in, 3 units (sabins/unit) | – | 1.1 | 2.2 | 7.5 | 7.5 | 8.6 | 9.7 | 11 | 9.7 | 9.7 | 8.6 | 9.7 | 9.7 | 9.7 | 8.6 | 7.5 | 7.5 | 6.5 | 7.5 |
| REGULARline Rg 0.8-5 · 7.9 in · ceiling raft 42 x 42 in, 3 units (sabins/unit) | – | 1.1 | 3.2 | 8.6 | 9.7 | 11 | 9.7 | 12 | 12 | 12 | 12 | 13 | 12 | 11 | 11 | 9.7 | 11 | 9.7 | 11 |
| BASICline Rg 2.5-16 · 9.8 in · ceiling raft 35 x 157 in (sabins/unit) | – | 5.4 | 15 | 22 | 28 | 31 | 34 | 38 | 37 | 34 | 34 | 39 | 38 | 40 | 37 | 37 | 36 | 32 | 31 |
| BASICline Rg 2.5-16 · 9.8 in · ceiling raft 35 x 79 in, 2 units (sabins/unit) | – | 3.2 | 7.5 | 12 | 14 | 17 | 19 | 18 | 18 | 18 | 18 | 20 | 20 | 20 | 19 | 19 | 17 | 17 | 17 |
| BASICline Rg 2.5-16, smooth edge · 9.8 in · ceiling raft 35 x 157 in (sabins/unit) | – | 5.4 | 14 | 20 | 28 | 30 | 34 | 36 | 37 | 34 | 32 | 36 | 36 | 34 | 31 | 28 | 25 | 23 | 18 |
| BASICline Rg 2.5-16 · 9.8 in · ceiling raft 35 x 157 in | – | 0.07 | 0.18 | 0.42 | 0.51 | 0.58 | 0.67 | 0.82 | 0.77 | 0.69 | 0.58 | 0.66 | 0.59 | 0.57 | 0.50 | 0.46 | 0.43 | 0.40 | 0.37 |
Measured values as a table (24 measurements)
Access frequency bands, variants and export. Create a permanent free account
Last updated: