Manufacturer

Fural Systeme in Metall GmbH

Fural manufactures modular metal ceiling systems with outstanding acoustic performance. Every metal ceiling is an acoustic ceiling with additional functions such as fire protection, cooling, heating, hygiene or impact resistance. Certified to TAIM, with EPDs available for steel and aluminium systems.

All products by this manufacturerManufacturer website

Documents

Fural Ceiling Raft

Ceiling Raft

EPD availableFree-hanging

Description

Free-hanging metal ceiling raft for flexible room acoustics, available as a single-piece or multi-piece version with a 55° or 90° folded edge. It can also be installed retrofit, without modifying the existing lighting. It can be combined with a cooling and heating function for later climate retrofitting. The structural ceiling remains visible and accessible for maintenance. Available formats: 2.88 m² (2.4x1.2 m), 3.45 m² (3x1.15 m), 1.35 m² (3x0.45 m), 2.70 m² (3x0.9 m), 4.05 m² (3x1.35 m), 2.88 m² (4.8x0.6 m), 3.60 m² (3x1.2 m), 1.96 m² (1.98 x 0.99 m).

Technical data

Material: galvanized steel
Surface: RAL 9010, powder coating 60–70 μm
Up to fire class: A1 (DIN EN 13501-1)
Application: Ceiling raft (free-hanging)

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)· 46 variants

Perforation

Size

Surface

NRC
1.25

Frequency values

αp per octave band

f (Hz)1252505001k2k4k
αp0.551.001.001.001.001.00

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

ComparePerforationSizeValue
Rv 1,6-20%7.9 in overall build-upNRC1.25
Rv 1,6-20%7.9 in overall build-upNRC1.35
Rg 2,5-16%7.9 in overall build-upNRC1.30
Rg 2,5-16%7.9 in overall build-upNRC1.25
Rg 2,5-16%7.9 in overall build-upNRC1.15
Rg 2,5-16%16 in overall build-upNRC1.05
P30-System7.9 in overall build-upNRC1.15
P30-System16 in overall build-upNRC1.20
Rg 2,5-16%4.1 in overall build-upNRC1.25
Rv 1,6-20%4.1 in overall build-upNRC1.00
Rd 1,5-22%7.9 in overall build-upNRC1.15
Rd 1,8-21%7.9 in overall build-upNRC1.10
Rd 1,5-22%7.9 in overall build-upNRC1.15
Rg 2,5-16%7.9 in overall build-upNRC1.10
Rg 2,5-16%7.9 in overall build-upNRC0.90
Rd 1,5-22%7.9 in overall build-upNRC1.05
Rg 0,7-4%7.9 in overall build-upNRC1.05
Rg 2,5-16%7.9 in overall build-upNRC0.75
Rg 2,5-16%7.9 in overall build-upNRC0.95
Rg 2,5-16%7.9 in overall build-upNRC0.85
Rg 2,5-16%7.9 in overall build-upNRC0.80
Rg 2,5-16%16 in overall build-upNRC0.75
Rg 2,5-16%7.9 in overall build-upNRC0.75
22,0 x 12,0 x 2,0 x 1,57.9 in overall build-upNRC0.85
22,0 x 12,0 x 2,0 x 1,57.9 in overall build-upNRC0.80
22,0 x 12,0 x 2,0 x 1,516 in overall build-upNRC0.85
Rg 2,5-16%7.9 in overall build-upNRC0.85
Rg 2,5-16%24 in overall build-upNRC0.90
Rg 2,5-16%16 in overall build-upNRC0.85
Rv 1,6-20%7.9 in overall build-upNRC0.70
Rg 2,5-16%7.9 in overall build-upNRC0.90
Rg 2,5-16%7.9 in overall build-upNRC0.95
Rg 2,5-16%7.9 in overall build-upNRC0.80
Rg 2,5-16%7.9 in overall build-upNRC0.75
Rg 2,5-16%7.9 in overall build-upNRC0.65
Rg 2,5-16%7.9 in overall build-upNRC0.70
Rg 2,5-16%7.9 in overall build-upNRC0.70
Rg 2,5-16%7.9 in overall build-upNRC0.75
Rg 2,5-16%31 in overall build-upNRC0.85
Rd 1,5-22%7.9 in overall build-upNRC0.70
Rg 2,5-16%7.9 in overall build-upNRC0.65
Rg 2,5-16%7.9 in overall build-upNRC0.65
Rg 0,7-4%7.9 in overall build-upNRC0.65
22,0 x 12,0 x 2,0 x 1,57.9 in overall build-upNRC0.45
glatt7.9 in overall build-upNRC0.65
Rg 2,5-16%2 in overall build-upNRC0.50

Test report: M 61840/21

NRC: 1.25 (derived from ISO 354 lab data)

Institute: MFPA Leipzig

Dimensions: 2.88 m² 2,4x1,2

Terms of use
Measured values as a table (46 measurements)
Fural Ceiling Raft: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz5000 Hz
Rv 1,6-20% · 200 mm overall build-up · Temperon-cooling coil, zwei 14 mm Verteilerrohre, 14 29 mm Registerrohre0.700.140.210.280.450.590.630.760.870.870.730.590.690.760.690.760.730.690.73
Rg 2,5-16% · 200 mm overall build-up · Temperon-cooling coil, zwei 14 mm Verteilerrohre, 14 29 mm Registerrohre0.750.170.240.310.520.690.690.830.900.940.830.690.760.800.760.800.730.730.73
Rg 2,5-16% · 200 mm overall build-up · cooling coil reproduced 2800x75, 12 pipe rows, 90 mm grid0.650.140.230.550.490.640.670.720.720.720.670.670.670.610.610.520.460.410.35
Rg 2,5-16% · 200 mm overall build-up · 13 strips 50x50x3000 mm mineral wool 44 kg/m³ in PE film , 90 mm Abstand, parallel to cooling coil, coverage ratio 57 % · cooling coil reproduced 2800x75, 8 pipe rows, 145 mm grid1.100.290.430.840.871.191.161.191.281.131.101.071.011.010.930.870.810.750.72
Rv 1,6-20% · 200 mm overall build-up · 50 mm mineral wool 100 kg/m³ in PE film1.250.380.520.690.971.081.221.251.321.391.321.321.351.391.281.221.181.081.01
Rv 1,6-20% · 200 mm overall build-up · 50 mm mineral wool 150 kg/m³ in PE film1.350.350.560.831.011.221.251.321.351.321.351.391.391.391.351.281.221.181.04
Rg 2,5-16% · 200 mm overall build-up · 50 mm mineral wool 150 kg/m³ in PE film1.300.380.560.831.011.221.281.321.351.351.351.391.391.351.321.251.181.111.01
Rg 2,5-16% · 200 mm overall build-up · 50 mm mineral wool 100 kg/m³ in PE film1.250.380.560.690.971.081.221.251.371.391.321.321.351.391.251.221.150.970.90
Rg 2,5-16% · 200 mm overall build-up · 13 strips 50x50x3000 mm mineral wool 44 kg/m³ in PE film , 90 mm Abstand, parallel to cooling coil, coverage ratio 57 % · cooling coil mock-up 2800x75, 12 pipe rows, 90 mm grid0.900.230.520.840.841.041.010.991.040.990.930.870.810.810.720.670.610.550.52
Rg 2,5-16% · 200 mm overall build-up · 34 strips 50x50x1150 mm mineral wool 44 kg/m³ in PE film , 90 mm Abstand, perpendicular to cooling coil, coverage ratio 57 % · cooling coil mock-up 2800x75, 12 pipe rows, 90 mm grid0.950.290.520.840.781.070.960.991.041.010.960.900.840.840.750.670.610.550.49
Rg 2,5-16% · 200 mm overall build-up · 50 mm mineral wool 100 kg/m³ in PE film · cooling coil mock-up 2800x75, 12 pipe rows, 90 mm grid0.950.380.670.900.961.131.011.041.071.010.960.900.870.870.780.700.640.580.52
Rg 2,5-16% · 200 mm overall build-up · Schmöle acoustic guide profile 4 pipe rows0.850.150.220.300.670.741.040.961.041.040.890.810.960.890.810.740.670.590.52
Rg 2,5-16% · 200 mm overall build-up · 6 Stk 3000 x 50 mm mineral-wool strips 50 mm wide 57 kg/m³ in PE film · Schmöle acoustic guide profile 8 pipe rows1.150.190.330.440.670.891.111.261.371.221.111.191.221.111.071.000.930.850.81
Rg 2,5-16% · 200 mm overall build-up · Schmöle acoustic guide profile 6 pipe rows0.800.070.220.260.520.630.810.891.000.930.780.740.850.810.780.780.700.630.56
Rg 2,5-16% · 200 mm overall build-up · Schmöle acoustic guide profile 10 pipe rows0.800.150.260.260.520.670.850.931.000.890.780.740.850.780.740.740.630.590.52
Rg 2,5-16% · 200 mm overall build-up · Schmöle acoustic guide profile 12 pipe rows0.750.170.200.300.520.640.770.840.910.890.790.720.810.770.720.690.640.570.49
Rg 2,5-16% · 400 mm overall build-up · Schmöle acoustic guide profile 12 pipe rows0.750.220.300.540.690.790.860.770.690.790.860.810.840.840.790.790.720.640.62
Rg 2,5-16% · 400 mm overall build-up · 50 mm mineral-wool strips 50 mm wide 57 kg/m³ in PE film · Schmöle acoustic guide profile 12 pipe rows1.050.250.420.620.810.910.990.890.961.141.191.211.231.191.111.091.040.960.86
Rg 2,5-16% · 200 mm overall build-up · Schmöle acoustic guide profile 12 pipe rows0.750.120.200.290.460.610.780.870.900.870.810.720.780.750.700.700.610.580.55
Rg 2,5-16% · 200 mm overall build-up · Schmöle WLP 12 pipe rows0.650.090.230.320.430.580.720.780.750.750.700.670.700.640.610.550.490.430.38
Rg 2,5-16% · 50 mm overall build-up0.500.070.100.070.100.100.170.210.310.420.590.690.800.870.900.900.800.630.56
Rg 2,5-16% · 200 mm overall build-up0.650.100.240.210.420.490.660.730.830.830.760.630.690.760.730.760.730.690.66
Rg 2,5-16% · 200 mm overall build-up0.750.070.170.350.490.590.660.830.900.900.760.660.760.830.800.800.760.730.69
P30-System · 200 mm overall build-up · 30 mm mineral wool in PE 80 kg/m³1.150.140.250.500.780.780.921.221.421.501.441.331.171.081.061.171.190.940.83
P30-System · 400 mm overall build-up · 30 mm mineral wool in PE 80 kg/m³1.200.140.280.690.830.780.891.141.251.501.611.471.281.191.251.331.391.110.94
Rg 2,5-16% · 200 mm overall build-up · Schmöle WLP 3 pipe rows, 1780x70, 200 mm grid0.700.110.190.300.480.560.740.780.850.890.780.670.740.780.740.700.700.670.63
Rg 2,5-16% · 200 mm overall build-up · 7 Stk. polyester wool-strips with 2400x50x25, 80 kg/m³ · Schmöle acoustic guide profile 8 pipe rows, 2800x75 mm, 110 mm grid0.900.110.260.440.630.700.931.041.111.111.000.891.000.960.960.930.890.850.81
Rg 2,5-16% · 105 mm overall build-up · 100 mm mineral wool 50 kg/m³ in PE film1.250.460.610.971.121.381.331.431.381.331.281.221.171.121.071.071.071.021.02
Rv 1,6-20% · 105 mm overall build-up · 3x polyester wool 20 kg/m³, 40 + 30 + 30 mm1.000.510.560.710.920.971.021.021.021.021.071.071.071.020.920.920.920.820.77
Rg 2,5-16% · 200 mm overall build-up0.700.070.170.270.420.540.670.790.860.890.770.640.740.810.770.810.790.770.72
Rd 1,5-22% · 200 mm overall build-up · 30 mm mineral wool 20 kg/m³ in PE film · cooling coil 2260x75, 8 pipe rows1.050.070.190.370.560.741.001.151.191.221.221.221.191.071.000.890.850.780.74
Rd 1,5-22% · 200 mm overall build-up · 30 mm mineral wool 25 kg/m³ in PE film · cooling coil 2260x75, 8 pipe rows1.150.220.410.700.810.961.111.261.301.331.261.261.221.151.040.930.890.850.85
Rd 1,5-22% · 200 mm overall build-up · cooling coil 2260x75, 8 pipe rows0.700.070.220.330.480.590.700.810.890.850.740.630.700.700.630.630.560.480.48
Rd 1,8-21% · 200 mm overall build-up · 30 mm mineral wool 45 kg/m³ in PE film · cooling coil 2260x75, 8 pipe rows1.100.150.370.700.810.891.071.261.261.301.331.301.261.191.040.930.890.850.81
Rd 1,5-22% · 200 mm overall build-up · 30 mm mineral wool 45 kg/m³ in PE film · cooling coil 2260x75, 8 pipe rows1.150.220.370.670.780.931.111.261.301.331.331.331.261.191.070.960.930.890.78
22,0 x 12,0 x 2,0 x 1,5 · 200 mm overall build-up · 20 mm polyester wool 20 kg/m³0.850.070.190.190.330.440.700.780.961.040.960.930.961.111.071.071.071.111.07
22,0 x 12,0 x 2,0 x 1,5 · 200 mm overall build-up · 20 mm polyester wool 20 kg/m³0.800.100.150.220.350.440.640.770.890.960.910.860.941.060.991.041.041.061.04
22,0 x 12,0 x 2,0 x 1,5 · 400 mm overall build-up · 20 mm polyester wool 20 kg/m³0.850.110.260.370.560.630.780.670.630.780.961.001.111.151.191.191.191.221.22
Rg 0,7-4% · 200 mm overall build-up · 30 mm mineral wool 45 kg/m³ in PE film · cooling coil 2260x75, 8 pipe rows1.050.220.440.850.810.931.041.221.221.191.191.191.071.040.890.810.740.740.67
Rg 0,7-4% · 200 mm overall build-up · cooling coil 2260x75, 8 pipe rows0.650.110.260.410.560.590.740.780.810.780.670.630.670.670.590.560.480.410.41
glatt · 200 mm overall build-up · 50 mm polyester wool 40 kg/m³0.650.220.440.700.740.810.890.810.780.700.630.520.560.520.440.410.370.370.37
Rg 2,5-16% · 200 mm overall build-up · 20 mm polyester wool 20 kg/m³0.850.110.150.220.330.440.700.780.931.000.930.891.041.111.111.111.071.071.07
Rg 2,5-16% · 600 mm overall build-up · 20 mm polyester wool 20 kg/m³0.900.150.330.440.560.520.520.590.780.810.961.041.191.261.261.261.261.371.30
Rg 2,5-16% · 800 mm overall build-up · 20 mm polyester wool 20 kg/m³0.850.150.330.440.440.410.560.560.700.850.961.041.151.261.221.261.261.331.30
Rg 2,5-16% · 400 mm overall build-up · 20 mm polyester wool 20 kg/m³0.850.150.300.410.560.630.740.630.630.810.961.001.111.191.151.221.221.301.19
22,0 x 12,0 x 2,0 x 1,5 · 200 mm overall build-up0.450.070.110.190.260.330.520.560.670.670.560.410.560.560.480.560.590.590.52
Measured values as a table (46 measurements)

Access frequency bands, variants and export. Create a permanent free account

Last updated: